The case
In partnership with ORANO Projets, Dynas+ developed a numerical fluid-structure interaction (FSI) model to assess the seismic behavior of a nuclear storage pool. The goal was to compare a full incompressible CFD (ICFD) modeling of the water with the classic Housner added-mass approach, in order to evaluate the influence of these two methods on the structural design of nuclear facilities.
The solution deployed
Dynas+ developed a fully coupled multiphysics model in LS-DYNA, combining:
- three-dimensional modeling of the concrete structure;
- explicit representation of the water volume using the ICFD solver;
- strong coupling between the fluid and the structure to simultaneously reproduce the pool's motion, pressure oscillations in the water, and surface waves under seismic loading;
- a reference model based on the Housner method for direct comparison of the two approaches.
Both models were subjected to the same seismic accelerograms in order to evaluate their effects on the structure's displacements, stresses, and internal forces.

The results achieved
The study highlights the benefits of explicit fluid-structure modeling for the seismic analysis of nuclear pools. The main results show:
- a realistic representation of water motion, pressure oscillations, and the waves generated by the earthquake;
- wall displacements 2 to 3 times smaller with the FSI model than with the Housner method;
- significantly reduced stresses, shear forces, and bending moments thanks to a more faithful representation of the fluid's behavior;
- the demonstration that, in this case study, the Housner method leads to a particularly conservative design, whereas an ICFD approach provides a more realistic estimate of the loads.
This work was the subject of a scientific paper presented at the 14th European LS-DYNA Conference 2023 (Baden-Baden): "ICFD Fluid structure interaction modeling for the seismic evaluation of a nuclear pool" (Nicolas Van Dorsselaer, Morgan Le Garrec, Vincent Lapoujade, Jean-Philippe Tardivel).